• Anti-static grounding strap and anti-static mat for handling bare M.2 card and 8300 system
• 1 x PCIe-based M.2 NVMe SSD, 2280 or 2242 size, B+M-key or M-key card
See also:
The M.2 slot accepts both 2280 and 2242 size cards, but the device ships with the retaining clip set for a 2280 size card
by default. This clip can easily be moved to accommodate a 2242 card without any tools.
2.9.3 Installation Procedure
The installation procedure has many steps which are broken down into related groups in the remainder of this document.
Follow all steps in the procedure carefully.
Take a Backup
If the system contains an existing configuration which should be carried over to the new installation, then the first step
is to take a backup of that configuration.
If the existing configuration is not necessary, this section may be skipped.
There are numerous backup options covered in the pfSense software documentation section on Backup and Restore.
For the purposes of reinstalling and restoring, the easiest method is to take a local backup.
Download the Installer
Before proceeding further, download a copy of the Netgate Installer amd64 memstick image using a Netgate Store
Account and write the installer to a USB memstick. For details, see Reinstalling pfSense Plus Software.
Power Off and Disconnect
Installing the SSD requires removing the top of the case to expose the internal components. For safety, before opening
the case, the Netgate 8300 must be completely disconnected from everything. This includes power, network cables,
USB cables, serial console cables, and any other external cables or devices connected to the Netgate 8300.
Danger: Reminder:
• Anti-static protection must be used throughout this procedure.
• Any hardware damage incurred during this procedure is not covered by the hardware warranty.
1. Turn power off to the unit by changing the power switch on the rear of the unit to the off position.
2. Unplug the power cables from all installed power supply units (PSUs).
Danger: Wait at least 60 seconds after unplugging power to proceed. This ensures that all phantom power
has dissipated.
The LED indicator on all installed PSUs should be off before proceeding.
3. Unplug all network cables, USB cables and devices, serial console connections, etc.
4. Dismount the Netgate 8300 from the rack
© Copyright 2024 Rubicon Communications LLC 74