ChipSHOUTER Users Manual: Serial Interface
53
Example:
# disarmed: set pulse width 120
# pulse width 120ns ...........[pulse width (nS)]
# pulse width 80ns(measured) ..[pulse width (nS)]
# disarmed: s p w 200
# pulse width 200ns ...........[pulse width (nS)]
# pulse width 160ns(measured) .[pulse width (nS)]
# armed: g p w
# pulse width 200ns ...........[pulse width (nS)]
# pulse width 160ns(measured) .[pulse width (nS)]
[get / set] pulse repeat [1..10000] [g / s] p r
Print or set value for number of pulses per trig-
ger, the trigger being the pulse command, the
front-panel button, or the RJ12 firmware pulse pin
when enabled.
Example:
#: set pulse repeat 1
#: s p r 5
[get / set] pulse deadtime [1..1000] [g / s] p d
Print or set value for time between pulses in mS,
the total pulse waveform will be repeat * deadtime
long.
[get / set] arm_timeout [0…60] [g / s] a
Print or set value for the automatic disarm timer
in minutes. The disarm time automatically happens
when no pulse has occurred in the arm_timeout
minutes, and is used to reduce temperature in the
ChipSHOUTER along with improving safety.

Table of Contents