ChipSHOUTER Users Manual: Serial Interface
56
get temperature <sensor> g temp <s>
Print temperature reading from one of the sensors.
Sensors are mosfet, xformer, and diode with asso-
ciated shorthand versions m, x, and d.
get triggersafe g ts
Print confirmation that device is ready to be
triggered. When triggering externally using the
hardware trigger input at fast repeat counts, it
is recommended to run this command in-between
trigger attempts. Running the command allows the
ChipSHOUTER to perform needed safety self-checks
that cannot be performed during the trigger event.
If the needed safety checks cannot be performed
for a certain length of time, the device will en-
ter fault mode.
[get / set] absent_temp [1..60] [g / s] at
Configure maximum time the temperature sensors can
be skipped for. The temperature sensors cannot be
read during pulse events, and the ChipSHOUTER
keeps a timer of how old the last temperature
reading is.
The timer is reset during routine self-checks (if
triggers are not coming in quickly), or in re-
sponse to the triggersafe command.
[get / set] pat_enable [1/0] [g / s] pat
Configure whether trigger caused by pulse com-
mand, front-panel button, or firmware trigger
input is simple [0] or pattern [1].

Table of Contents