EasyManua.ls Logo

NewAE CHIPSHOUTER CW520 - Page 55

NewAE CHIPSHOUTER CW520
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ChipSHOUTER Users Manual: Serial Interface
55
get fault_active g fa
Print any active faults, for example the current
state of the probe open detection.
get fault_latch g fl
Print any latched faults, which may not be cur-
rently active but occurred once and must be
cleared manually.
get fault [latched / current] <type> g f [l / c] <t>
Get the state of a specific fault, current or
latched. <type> is the fault type, and <t> is the
associated shorthand. Table of <type> options be-
low.
Details on fault meanings
and troubleshooting can
be found in the faults
section of this manual.
Fault
Shorthand
probe
p
overtemp
ot
open
o
highv
hv
ramcrc
rc
eecrc
e
gpio
g
charge
cf
trigger
t
hw
h
trig_g
tg
overvoltage
ov
temp_sensor
ts