20
1. Press MENU to enter the Setup Menu. PAGE/MUTE SETUP will be listed in the menu options.
Use ▼ on the Navigation Array to scroll through the menu options to Page/Mute Setup. When
► appears to the left of Page/Mute Setup, Press ENTER. The Display will change to the
Page/Mute Setup Window.
2. The Page/Mute Setup Window will default to [ZONE 1].
3. Press ► in the Navigation Array. The Programming Brackets [] will move to MUTE [N]. (All
zones default to [N] or no zone mute.)
4. Press ▲ or ▼ in the Navigation Array to change zone mute status to [Y] (allow zone mute) as
desired.
5. Press ► to advance the programming brackets to Pg.[N] (All zones default to [N] or no zone
paging.)
6. Press ▲ or ▼ in the Navigation Array to change zone page status to [Y] (allow paging) as
desired.
7. Press ◄ to return to the [SELECTED ZONE].
8. Press ▲ or ▼ to navigate to the previous or next [ZONE].
9. Repeat steps 3-6 for all zones as needed.
10. Press ENTER when MUTE and PAGE have been configured for all active zones. A new
window will appear on the Display showing: PAGE TIMEOUT: [10] Sec and MUTE TIMEOUT:
[10] Sec. (All zones default to 10 seconds for both functions. If [N] is selected for either function in
any zone, the function will be inactive for that zone.)
11. Press ▲ or ▼ to adjust the PAGE TIMEOUT. (Page timeout can be set from 1-60 seconds.)
The timeout setting will affect all zones set for paging.
NOTE: Page timeout can be used to convert a 12V pulse to a page timeout up to 60 seconds. A
constant voltage will ‘hold’ the page function as long as voltage is present on the PAGE terminal.
For constant voltage, set page timeout to 0 seconds or additional seconds will be added to page
timeout after the voltage has been removed.
12. Press ► to advance the Programming Brackets to set MUTE TIMEOUT duration.
13. Press ▲ or ▼ to adjust the MUTE TIMEOUT. (Mute timeout can be set from 1-60 seconds.)
The timeout setting will affect all zones set for mute.
NOTE: Mute can be used to convert a 12V pulse to a zone mute up to 60 seconds. A constant
voltage will ‘hold’ the mute function as long as voltage is present on the MUTE terminal. For
constant voltage, set mute timeout to 0 seconds or additional seconds will be added to mute
timeout after the voltage has been removed.
14. Press ENTER. SETTINGS SAVED will appear on the display for a few seconds. The Display
will switch to the Setup Menu.
15. Press Menu to return to the default Tuner Preset Window.
Zone Sharing
There are two modes for linking zones with the C-6. One is GROUP and the other is ZONE
SHARING. Group is a temporary linking of active zones by source and volume. Zone Sharing has
two options. One, volume/power follows [Y], permanently links up to three zones by power,
source and volume in the System Setup. The second, volume/power follows [N] permanently links
up to three zones but only by source when active. To program Zone Sharing:
1. Press MENU to enter the Setup Menu. ZONE SHARING will be listed in the menu options. Use
▼ in the Navigation Array to scroll through the menu options to Zone Sharing Setup. When ►
appears to the left of Zone Sharing Setup, Press ENTER. The Display will change to the Zone
Sharing Setup Window.
2. The Zone Sharing Setup Window will default to: ZONES: [00] 00 00.
3. Press ▲ in the Navigation Array to select the FIRST ZONE to be linked.
4. Press ► to advance the Programming Brackets [] to 00 (the next zone to be linked).
5. Press ▲ or ▼ in the Navigation Array to select the SECOND ZONE to be linked.
6. Press ► to advance the Programming Brackets to 00 (the next zone to be linked).
7. Press ▲ or ▼ in the Navigation Array to select the THIRD ZONE to be linked.
8. Press ► to advance the Programming Brackets to Vol/Pwr Follows? [N]. (Default is source link
only.)
9. Press ▲ or ▼ to select Vol/Pwr Follows? [Y] if desired. (Links power, source and volume.)

Related product manuals