Energy labelling
Information sheet
NIBESupplier
F470Model
35 / 55°CTemperature application
L
Declared load profile for water heating
A+ / A+
Seasonal space heating energy efficiency class, average
climate
A
Water heating energy efficiency class, average climate
3 / 3kWRated heat output (Pdesignh), average climate
1505 / 1806kWhAnnual energy consumption space heating, average
climate
1299kWhAnnual energy consumption water heating, average
climate
140 / 116%Seasonal space heating energy efficiency, average cli-
mate
79%Water heating energy efficiency, average climate
52dBSound power level L
WA
indoors
3 / 3kWRated heat output (Pdesignh), cold climate
3 / 3kWRated heat output (Pdesignh), warm climate
1737 / 2091kWhAnnual energy consumption space heating, cold cli-
mate
1299kWhAnnual energy consumption water heating, cold cli-
mate
973 / 1168kWhAnnual energy consumption space heating, warm cli-
mate
1299kWhAnnual energy consumption water heating, warm
climate
145 / 120%Seasonal space heating energy efficiency, cold climate
79%Water heating energy efficiency, cold climate
140 / 116%Seasonal space heating energy efficiency, warm cli-
mate
79%Water heating energy efficiency, warm climate
-dBSound power level L
WA
outdoors
Data for energy efficiency of the package
F470Model
35 / 55°CTemperature application
VIIController, class
3.5%Controller, contribution to efficiency
143 / 119%Seasonal space heating energy efficiency of the pack-
age, average climate
A+ / A+
Seasonal space heating energy efficiency class of the
package, average climate
148 / 123%Seasonal space heating energy efficiency of the pack-
age, cold climate
143 / 119%Seasonal space heating energy efficiency of the pack-
age, warm climate
The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added
to the package, the overall efficiency of the package should be recalculated.