Menu 7.2 - logging
logging7.2
activated
interval
sec
5
Setting range: 1 s – 60 min
Factory setting range: 5 s
Here you can choose how current measurement values
from VVM 320 should be saved onto a log file on the
USB memory.
1.
Set the desired interval between loggings.
2.
Tick “activated".
3.
The present values from VVM 320 are saved in a
file in the USB memory at the set interval until “ac-
tivated" is unticked.
NOTE
Untick "activated" before removing the USB
memory.
Logging floor drying
Here you can save a floor drying log on the USB memory
and in this way see when the concrete slab reached the
correct temperature.
• Make sure that "floor drying function" is activated in
menu 5.9.
• Select "logging floor drying activated".
• A log file is now created, where the temperature and
the immersion heater output can be read off. Logging
continues until "logging floor drying activated" is
deselected or until "floor drying function" is stopped.
NOTE
Deselect "logging floor drying activated" before
you remove the USB memory.
Menu 7.3 - manage settings
manage settings 7.3
save settings
recover settings
Here you can manage (save as or retrieve from) all the
menu settings (user and service menus) in VVM 320
with a USB memory.
Via "save settings" you save the menu settings to the
USB memory in order to restore them later or to copy
the settings to another VVM 320.
NOTE
When you save the menu settings to the USB
memory you replace any previously saved
settings on the USB memory.
Via "recover settings" you reset all menu settings from
the USB memory.
NOTE
Reset of the menu settings from the USB
memory cannot be undone.