Menu 1 - INDOOR CLIMATE
Overview
1.1.1 - temperature heating1.1 - temperature1 - INDOOR CLIMATE
1.1.2 - temperature cooling *
1.2 - ventilation *
1.3.1 - heating1.3 - scheduling
1.3.2 - cooling *
1.3.3 - ventilation *
1.9.1.1 heating curve1.9.1 - curve1.9 - advanced
1.9.1.2 - cooling curve *
1.9.2 - external adjustment
1.9.3 - min. flow line temp.
1.9.4 - room sensor settings
1.9.5 - cooling settings *
1.9.6 - fan return time *
1.9.7.1 - heating1.9.7 - own curve
1.9.7.2 - cooling *
1.9.8 - point offset
1.9.11 - +Adjust
* Accessories are needed.
Sub-menus
For the menu INDOORCLIMATE there are several sub-
menus. Status information for the relevant menu can
be found on the display to the right of the menus.
temperature Setting the temperature for the climate
system. The status information shows the set values
for the climate system.
ventilation Setting the fan speed. The status informa-
tion shows the selected setting. This menu is only dis-
played if the exhaust air module is connected (access-
ory).
scheduling Scheduling heating, cooling and ventila-
tion. Status information "set" is displayed if you set a
schedule but it is not active now, "holiday setting" is
displayed if the vacation schedule is active at the same
time as the schedule (the vacation function is priorit-
ised), "active" displays if any part of the schedule is
active, otherwise it displays " off".
advanced Setting of heat curve, adjusting with extern-
al contact, minimum value for supply temperature,
room sensor, cooling function and +Adjust.
Menu 1.1 - temperature
If the house has several climate systems, this is indicated
on the display by a thermometer for each system.
In Menu 1.1 choose between heating or cooling and
then set the desired temperature in the next menu
"temperature heating/cooling".
Set the temperature (with room sensors installed
and activated):
heating
Setting range: 5 30 °C
Default value: 20
cooling (accessory is required)
Setting range: 5 30 °C
Default value: 25
The value in the display appears as a temperature in
°C if the climate system is controlled by a room sensor.
Caution
A slow heat-releasing heating system, such as
for example, underfloor heating, may not be
suitable for control using the heat pump's
room sensor.
To change the room temperature, use the control knob
to set the desired temperature in the display. Confirm
the new setting by pressing the OK button. The new
temperature is shown on the right-hand side of the
symbol in the display.