Menu 5.10 - change log
Read off any previous changes to the control system
here.
The date, time and ID no. (unique to certain settings)
and the new set value is shown for every change.
NOTE
The change log is saved at restart and remains
unchanged after factory setting.
Menu 5.11 - heat pump settings
Settings for installed heat pump can be made in the
submenus.
Menu 5.11.1 - EB101
Make settings specifically for the installed heat pump
and heating medium pump here.
Menu 5.11.1.1 - heat pump
Make settings for the installed heat pump here. To see
what settings you can make, see installation manual
for the heat pump.
Menu 5.11.1.2 - heating medium pump (GP1)
op. mode
Setting range: auto / intermittent
Default value: auto
Set the operating mode of the heating medium pump
here.
auto: The heating medium pump runs according to
the current operating mode for VVM 325.
intermittent: The heating medium pump starts and
stops 20 seconds before and after the compressor in
the heat pump.
speed during operation
heating, hot water, pool, cooling
Setting range: auto / manual
Default value: auto
Manual setting
Setting range: 1–100 %
Default values: 70 %
max. allowed speed
Setting range: 80–100 %
Default values: 100 %
speed in wait mode
Setting range: 1–100 %
Default values: 30 %
Set the speed at which the heating medium pump is
to operate in the present operating mode. Select "auto"
if the speed of the heating medium pump is to be
regulated automatically (factory setting) for optimal
operation.
If "auto" is activated for heating operation, you can
also make the setting "max. allowed speed" which re-
stricts the heating medium pump and does not allow
it to run at a higher speed than the set value.
For manual operation of the heating medium pump
deactivate "auto" for the current operating mode and
set the value to between 1 and 100 % (the previously
set value for "max. allowed speed" no longer applies).
wait mode means heating or cooling operating modes
for the heating medium pump, when the heat pump
has neither a need for compressor operation nor elec-
trical addition and slows down.
5.12 - country
The country where the heat pump is installed is selected
here.
NOTE
Once you have selected country, you have 24
hours to undo the selection. Afterwards, it is
not possible to change the country selected.