14
Programming Interface
• All codes are four (4) digits in length.
• Entry code is a four (4) digit code needed to activate the gate.
• Master Code is needed to add, remove or reset entry codes.
• Master Code also functions as the entry code under normal operation.
• Factory default Master Code is 1234.
• STATUS light should blink and beeper should beep (once) whenever any button is pressed.
• If more than 10 seconds elapsed between key presses the unit returns to normal (idle) operating mode.
• Keypad can only enter program mode from sleep mode (keypad is turned OFF).
• Keypad will beep three times before going into sleep mode.
Program New Master Code
• Press and release the PROGRAM button.
• Enter the old Master Code then press and release PROGRAM button.
• Enter 0, 6 then press and release PROGRAM button
• Enter the new Master Code then press and release PROGRAM button.
• Enter the new Master Code then press and release PROGRAM button again for conrmation.
• Beeper beeps 3 times to conrm that the new Master Code is accepted.
NOTE: If the Master Code is not a matched pair or error occurs, (i.e. if the entry code is NOT a 4-digit code)
the STATUS light will ash rapidly and the beeper will sound for 2 seconds before returning to normal
operation with old Master Code.
Example: Key press sequence to change old Master Code from 1 2 3 4 to 3 1 2 1
1 2 3 4 0 6 3 1 2 1 3 1 2 1
The round black dot in the above example is the ‘PROGRAM’ button.
Program (Add) New Entry Code
• Press and release PROGRAM button.
• Enter the Master Code then press and release PROGRAM button.
• Enter 0, 2 then press and release PROGRAM button.
NOTE: If memory is full (all 25 locations are already programmed) the STATUS light will ash rapidly and the
beeper will sound for 2 seconds before returning to normal operation without saving.
• Enter the new Entry Code then press and release PROGRAM button.
• Beeper beeps 3 times to conrm that the new Entry Code is accepted.
NOTE: If the code is NOT 4-digits in length or an error condition has occurred. The STATUS light will ash
rapidly and the beeper will sound for 2 seconds before returning to normal operation without saving.
Example: Key press sequence to add ‘3456’ as a new entry code. (1234 is the Master Code)
The round black dot in the above example is the ‘PROGRAM’ button.
Programming the Keypad
1 2 3 4 0 2 3 4 5 6