20
7.2.6) Examples of LEVEL 2 programming
This example shows the sequence of operations required to change the factory setting of the parameters and set the functions of “Belt
Recovery” to no recovery (input on L2 and level on L1) and set “Closing slowdown” to long (input on L3 and level on L3).
1. Switch off SPIN (for example by removing fuse F1)
2. Press and hold [Set]
3. Switch on SPIN (for example by inserting fuse F1)
4. Wait for the flashing signal indicating control unit start-up and keep [Set] pressed until L1 starts to flash
(approx. 6s) L1 6s
5. Release [Set]
6. Press the key []once to move the flashing led onto led L2
L2
7. Press and hold [Set] during steps 8 and 9
8. Wait approx. 3s until led L2 lights up, indicating the current level of “Belt recovery”
L2 3s
9. Press the key []once to move the illuminated led onto L1, to eliminate “Belt recovery”
L1
10. Release [Set]
11. Press the key []once to move the flashing led onto led L3
L3
12. Press and hold [Set] during steps 13 and 14
13. Wait approx. 3s until led L2 lights up, indicating the current level of “Closing slowdown”.
L2 3s
14. Press the key []once to move the illuminated led onto L3, indicating the new value of
“Closing slowdown”. L3
15. Release [Set]
16. Wait 10s to exit the programming mode automatically after the maximum time interval.
10s
Table 20: Example of LEVEL 2 programming in “Programming on power-up” mode Example
This example shows the sequence of operations required to change the factory setting of the parameters and set the functions of “Motor
Force” to high (input on L1 and level on L3) and increase the “Pause Time” to 60s (input on L3 and level on L3).
1. Press and hold [Set] for approx. 3s
3s
2. Release the key [Set] when led L1 starts to flash
L1
3. Press and hold [Set] during steps 4 and 5
4. Wait approx. 3s until led L2 lights up, indicating the current level of “Motor Force”
L2 3s
5. Press the key []once to move the illuminated led onto L3, indicating the new value of “Motor Force”
L3
6. Release [Set]
7. Press []twice to move the flashing led onto led L3
L3
8. Press and hold [Set] during steps 9 and 10
9. Wait approx. 3s until led L2 lights up, indicating the current level of “Pause Time”.
L2 3s
10. Press the key []once to move the illuminated led onto L3, indicating the new value of “Pause Time”.
L3
11. Release [Set]
12. Wait 10s to exit the programming mode automatically after the maximum time interval.
10s
Table 20a: Example of LEVEL 2 programming in “Standard programming” mode Example