www.usmotors.com
ID300/302 Integrated Motor Drive | Connections
29
4.6.1 Terminal Characteristics
Refer to Section 4.6 on page 28 for proper isolation of cables.
1 +10V Size 3 Drive
Function
Supply for external analog devices
Nominal Voltage
10.2 V
Voltage Tolerance
± 3%
Max Output Current
5mA
2 ADI1 Analog or digital input 1
4 ADI2 Analog or digital input 2
AD11 Default Function
10.2 V
AD12 Default Function
± 3%
Type of Input
5mA
Resolution
Sample Rate
Operating in Voltage Mode
Full Scale Voltage Range 0 V to ± 3%
MaxOset ± 30 mV
Absolute Max Voltage Range -18 V to +30 V relative to 0 V
Input Resistance 100kΩ
Operating in Current Mode
Current Range 0 to 20 mA ± 5 %
MaximumOset 250μA
Load Impedance 165kΩ
Operating in Digital Mode
Impedance 6.8kΩ
Input Threshold 10 V ± 0.8 V (IEC 61131-2)
Operating in Thermistor Mode (ADI2 Only)
Voltage Range ± 10 V
Input Threshold >3.3kΩ
Reset Threshold
<1.8kΩ
Bias for DIN44081 (PTC), PT1000, PT2000, etc.
3 0V
Function
Common connection for all external devices