Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running the
motor
Optimization
NV Media
Card
Onboard
PLC
Advanced
parameters
Diagnostics UL Listing
Unidrive M200 / M201 Control User Guide 115
Issue Number: 2
* With Unidrive M201, the default is PAd (5).
11.13 Menu 12: Threshold detectors, variable selectors and brake control function
Figure 11-19 Menu 12 logic diagram
11.081 Drive Name Characters 9-12
(-2147483648) to
(-2147483647)
- - - - (757935405) RW Chr PT US
11.082 Drive Name Characters 13-16
(-2147483648) to
(-2147483647)
- - - - (757935405) RW Chr PT US
11.084 Drive Mode OPEn.LP (1), rFC-A (2)
RO Txt ND NC PT
11.085 Security Status
NonE (0), r.onLy.A (1), StAtUS (2),
no.Acc (3)
RO Txt ND NC PT PS
11.086 Menu Access Status LEVEL.1 (0), LEVEL.2 (1), ALL (2)
RO Txt ND NC PT PS
11.091 Additional Identifier Characters 1 (-2147483648) to (2147483647)
RO Chr ND NC PT
11.092 Additional Identifier Characters 2 (-2147483648) to (2147483647)
RO Chr ND NC PT
11.093 Additional Identifier Characters 3 (-2147483648) to (2147483647)
RO Chr ND NC PT
11.094 Disable String Mode Off (0) or On (1) Off (0) RW Bit PT US
11.097 AI ID Code
NonE (0), Sd.CArd (1), rS-485 (2),
boot (3), rS-485 (4)
RO Txt ND NC PT
11.098 24V Alarm Loss Enable Off (0) or On (1) Off (0) RW Bit US
11.099 Modbus Parameter Conversion 0000 to 1111 0000 RW Bin US
Parameter
Range () Default ()
Type
OL RFC-A OL RFC-A
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination
IP IP address Mac Mac address Date Date parameter Time Time parameter SMP Slot,menu,parameter Chr Character parameter Ver Version number
??.???
Any variable
parameter
??.???
12.003
Threshold
Detector 1
Source
12.004
Threshold
Detector 1
Threshold
Detector 1
x(-1)
12.006
Threshold
Detector 1
Output Invert
12.001
12.005
Threshold
Detector 1
Hysteresis
??.???
Any
??.???
Any variable
parameter
??.???
12.023
Threshold
Detector 2
Source
12.024
Threshold
Detector 2
Level
Threshold
Detector 2
Threshold
Detector 2
x(-1)
12.002
Threshold
Detector 2
Output
12.025
Threshold
Detector 2
Hysteresis
are shown
at their default setting
Threshold
level
Threshold
output
Threshold
Detector 1
Level
Threshold
Detector 1
Output
mm.ppp
mm.ppp
Key
(RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
The parameters are all shown in their default settings