EasyManua.ls Logo

Nikon DTM Series - !AVE; !PNO; !PSM; !T-P

Nikon DTM Series
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Nikon Communication Interface Manual
P16/34
b) Data set command
!AVE
Input + 0 - 1 : Number of averaging measurement (“00” – “99”)
Output None
Remarks
Set an average count of the measurement. It is set to [MSR] (or [MSR1]) key only.
!PNO
Input + 0 - 6 : Point number (7 digits)
Output None
Remarks Set a default point number/name (7-digit PT)
!PSM
Input + 0 - 3 : Prism constant ("-999" - "999")
Output None
Remarks
Set the prism constant. It is set to [MSR] (or [MSR1]) key only.
!T-P
Input + 0 - 2 : Air temperature
+ 3 : " "
+ 4 - 7 : Air pressure
Output None
Remarks Set the current temperature and pressure.
!HAN
Input + 0 - 6 : Horizontal angle (7 digits)
Output None
Remarks Set the horizontal angle. (in 7 digits)
Confidential