Nikon Communication Interface Manual
P10/34
5-5. Format of commands
a) Remote control command
$MSR
Input None
Output None
Remarks
Taking a distance measurement in Precise mode.
Resolution and average of current settings are used in the measurement.
When the Data output after MSR” feature is set to ON, the measured data is to be
output in the specified format.
$TRK
Input None
Output None
Remarks
Taking a distance measurement in Normal mode.
Resolution and average of current settings are used in the measurement.
When the “Data output after MSR” feature is set to ON, the measured data is to be
output in the specified format.
$HTR
Input None
Output None
Remarks
Initiate continuous distance measurements. (AVE=0)
Resolution is fixed to COARSE mode.
When the “Data output after MSR” feature is set to ON, the measured data is to be
output in the specified format.
$SHV
Input None
Output None
Remarks Change display. (Same as [DSP] key on the instrument.)
$RHA
Input None
Output None
Remarks Reset the horizontal angle to zero.
$BZR
Input + 0 : Length (1 to 9)
Output None
Remarks $BZRn; Beep a tone for “Length” x 50 msec.
Confidential

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nikon DTM Series and is the answer not in the manual?

Nikon DTM Series Specifications

General IconGeneral
TypeTotal Station
Power SourceRechargeable battery
Magnification30x
DisplayLCD
Internal MemoryVaries by model
Environmental ResistanceIP66
DimensionsVaries by model
ApplicationsSurveying, construction