EasyManuals Logo

Nikon DTM Series User Manual

Nikon DTM Series
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Nikon Communication Interface Manual
P7/34
5-3. Commands/Data format
Three types of commands are available;
a) Remote control command: Change function. Most commands do not follow any data output.
b) Data set command: Set instrument settings such as temperature, pressure etc. No data output follows.
c) Data output command: Output measured data, setting data etc. Follows data output.
Keyword
Remote control command “$”
Data set command “!”
Data output command: “?”
Each command consists of a keyword, three characters. Parameters are added when necessary.
Keyword
($/!/?)
Char-1 Char-2 Char-3 Parameter…
An asterisk is added in front of the keyword when the extended command is to be used.
*
Keyword
($/!/?)
Char-1 Char-2 Char-3 Parameter…
Confidential

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nikon DTM Series and is the answer not in the manual?

Nikon DTM Series Specifications

General IconGeneral
TypeTotal Station
Power SourceRechargeable battery
Magnification30x
DisplayLCD
Internal MemoryVaries by model
Environmental ResistanceIP66
DimensionsVaries by model
ApplicationsSurveying, construction

Related product manuals