EasyManua.ls Logo

Nilfisk-Advance MC 6P - Storing the Cleaner (below 0°C)

Nilfisk-Advance MC 6P
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
1)
Options / model variants
Original instructions
MC 5M - MC 6P - MC 7P
,
6.5 Storing the cleaner
(below 0°C)
Store the cleaner in a dry room without danger of frost or protect as
below:
CAUTION!
If the high-pressure cleaner is stored in a room with temperatures
around or below 0°C, anti-freeze should be drawn into the pump
beforehand:
1. Remove the water inlet hose from the cleaner.
2. Remove the spray lance.
3. Switch on the cleaner with the main switch in position
" I " and activate trigger on the spray gun.
Switch off the cleaner after max. 3 minutes.
4. Connect the suction hose to the water inlet of the cleaner and
place it in a tank containing anti-freeze.
5. Switch on the cleaner with the main switch in position " I ".
6. Hold the spray gun over the tank containing anti-freeze and oper-
ate it to start suction.
7. During suction operate the spray gun two or three times.
8. Lift the suction hose from the tank containing anti-freeze and op-
erate the spray gun to pump off the remaining antifreeze.
9. Switching off the cleaner
10. To avoid any risks, store the cleaner temporarily in a heated room
before using it again.
2. At last turn, lock the cable
end in the cable lock (C).
C