1)
Options / model variants
Original instructions
MC 5M - MC 6P - MC 7P
8 Troubleshooting
Fault Cause Remedy
Pressure drop Air in the system Vent the system by
operating the spray gun
several times at short
intervals. If necessary,
operate the cleaner for a
short time without the high-
pressure hose connected.
High pressure nozzle blocked
worn
Clean/replace the high
pressure nozzle
Detergent tank empty Top up detergent tank or
set detergent to “0”
Pressure uctuations Pump draws in air (only
possible in suction mode)
Check that the suction set
is air-tight
Lack of water Open water tap
Water inlet hose is too long
or its cross-section too small
Use a water inlet hose
that can provide the water
ow (Q
max
) de ned for the
machine
Lack of water caused by
blocked water lter
Clean the water lter in the
water connection (never
work without water lter)
Lack of water because max.
permissible suction height
has not been heeded
See instructions
The motor does not start when
the cleaner is switched on
The plug is not inserted
properly, i.e. there is no
current
Oil level too low
Check the plug, lead and
switch and if necessary
have them replaced by a
skilled electrician
Check oil/add oil
The mains fuse is switched
off
The overload protection
has been activated due to
overheating or overloading of
the motor
Switch on the mains fuse
Check that the mains
voltage and the cleaner
voltage are the same.
Switch off the cleaner and
allow it to cool for at least 3
minutes
When the cleaner is switched
on the motor buzzes without
starting
The mains voltage is too low
or there is a phase failure.
Have the electrical
connection checked
The pump is blocked or
frozen
Contact the Nil sk
customer service
Incorrect cross-section or
length of the extension lead
Use lead with correct cross
section or length
The motor switches off The overload protection
has been activated due to
overheating or overloading of
the motor
Check that the mains
voltage and the cleaner
voltage are the same.
Switch off the cleaner and
allow it to cool for at least 3
minutes
High-pressure nozzle is dirty Change the high-pressure
nozzle

Other manuals for Nilfisk-Advance MC 6P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance MC 6P and is the answer not in the manual?

Nilfisk-Advance MC 6P Specifications

General IconGeneral
BrandNilfisk-Advance
ModelMC 6P
CategoryPressure Washer
LanguageEnglish

Related product manuals