22Service Manual – SC6000 04 - Control System
• Other Main Controller outputs
Dust Guard Solenoid L2 – See above (same as dust guard pump)
Horn H1
Always active. Follows S3 horn switch input.
Back up alarm H2
Must be enabled in conguration menu
Throttle command <0%
Headlights LP1 and LP2
Headlight option set to “Yes” in conguration menu
Always active
Follows headlight membrane switch input
Will start out “on” if Headlights set to “on” In the options menus
• Drive Controller outputs
Drive wheel motor
No “interlock” message from the main controller on the CAN bus (only active during auto disc brush
install mode)