50Service Manual – SC900 30 - Solution System
EcoFlex Control Panel
For machines equipped with the option EcoFlex
system, the standard solution control panel is
replaced with the EcoFlex control panel.
1. Remove the 4 screws that secure the control
panel to the solution tank, and lift the panel
away from the tank.
2. Disconnect the electrical connector, and
remove the control panel.
Specications
Parameter Range
Solution Solenoid
Coil Resistance
105Ω
Detergent Pump Coil Resistance 37Ω
A
B