EasyManuals Logo

Nilfisk-Advance SOL 3 User Manual

Nilfisk-Advance SOL 3
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
03/2009
4
SOL 3 / SOL 5 W / BDC 3122 / BDC 3140 / E-VAC3000
GB
Extensions
If an extension is used, make sure it is t for the power draw
and protection degree of the vacuum cleaner.
Minimum section of extension cables:
Maximum length = 20 m
Cable = HO7 RN - F.
Max power (kW) 3 5 15 22
Minimum section (mm
2
) 2.5 4 10 16
WARNING!
Sockets, plugs, connectors and installation of the
extension cable must maintain the IP protection
degree of the vacuum cleaner, as indicated on the
data plate.
WARNING!
The vacuum cleaner’s power socket must be
protected by a differential circuit-breaker with surge
current limitation, that shuts off the power supply
when the current dispersed towards ground exceeds
30 mA for 30 ms or an equivalent protection circuit.
WARNING!
Neverspraywateronthevacuumcleaner:suchaction
constitutes a danger hazard for persons and could
short circuit the power supply. Consult the latest
edition of the European Union Directives, the Laws
in the country of use and the current standards in
force (UNI - CEI - EN), particularly European standard
EN60335-2-69.
Setting to work - connection to the power
supply
WARNING!
■ Makesurethatthevacuumcleanerisinperfect
condition before commencing work.
■ Beforepluggingthevacuumcleanerintothe
electrical mains, make sure that the voltage rating
indicated on the data plate corresponds to that of
the electrical mains.
■ Plugthevacuumcleanerintoasocketwitha
correctly installed ground contact/connection.
Makesurethatthevacuumcleanerisoff.
■ Theplugsandconnectorsoftheconnection
cables must be protected against splashed water.
■ Makesurethatconnectionstotheelectrical
mains and plug are correct.
■ Usethevacuumcleanersonlywhenthecables
that connect to the electrical mains are in perfect
condition (damaged cables could lead to electric
shocks!).
■ Regularlycheckthattheelectriccabledoesnot
show signs of damage excessive wear, cracks or
ageing.
WARNING!
Whenthevacuumcleanerisoperating:
■ Donotcrush,pull,damageortreadonthecable
that connects to the electrical mains.
■ Onlydisconnectthecablefromtheelectrical
mains by removing the plug (do not pull the
cable).
■ Onlyreplacetheelectricpowercablewithone
ofthesametypeastheoriginal:HO7RN-F.The
same rule applies if an extension is used.
■ Thecablemustbereplacedbythemanufacturer’s
ServiceCentrestafforbyequivalentqualied
personnel.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance SOL 3 and is the answer not in the manual?

Nilfisk-Advance SOL 3 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelSOL 3
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals