03/2009
10
SOL 3 / SOL 5 W / BDC 3122 / BDC 3140 / E-VAC3000
GB
Fault Causes Remedies
The vacuum cleaner suddenly stops
Clogged main lter
Shake the lter.
Replace it if this is not sufcient.
Clogged vacuum hose Check the vacuum hose and clean it.
Circuit breaker activation
Check the setting.
Check the motor electrical input.
Empty the container.
Contact an authorized after-sales
service centre if necessary.
Dust leaks from the vacuum cleaner The lter is torn
Replace it with another of identical
category.
Electrostatic current on the vacuum
cleaner
Non existent or inefcient grounding
Check all ground connections.
Especially check the inlet.
Lastly, the hose must be strictly
antistatic.
Liquid leaks from the vacuum cleaner
The level monitoring function does not
work
Contact an authorized Service Centre.
The vacuum cleaner does not start
after emptying the container
The level monitoring hose is clogged
Release the container and clean the
level sensor.
Troubleshooting