7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
Virtual Chassis
Edition: 01 3HE 16132 AAAB TQZZA 237
The following output shows an example of a BOF configuration for a CPM-
IMM node.
A:Dut-A# show bof
========================================================================
BOF (Memory)
========================================================================
primary-image ftp://*:*@135.250.127.36/./images/7xxx-hops/
primary-config cf1:\default.cfg
#eth-mgmt Port Settings:
no eth-mgmt-disabled
eth-mgmt-address 10.135.17.166/24 active
eth-mgmt-address 10.135.17.167/24 standby
eth-mgmt-route 10.250.0.0/16 next-hop 10.135.17.1
eth-mgmt-autoneg
eth-mgmt-duplex full
eth-mgmt-speed 100
#System Settings:
wait 3
persist off
console-speed 115200
no console-disabled
vc-stack-name VC-3
vc-stack-node-type cpm-imm
vc-stack-node cpmA slot-num 1 mac-addr d0:99:d5:91:1c:41
vc-stack-node cpmB slot-num 2 mac-addr d0:99:d5:90:1e:41
=======================================================================
Step 7. On the node that will be the standby CPM for the first time boot, log in
through the console port and manually interrupt the boot process.
The boot prompt appears.
Step 8. Configure BOF parameters as follows:
- specify standalone-vc for the boot loader parameter chassis-role
- specify a name for or the boot loader parameter vc-stack-name
- specify cpm-imm for the boot loader parameter vc-stack-node-type
- specify the slot number and MAC address of each CPM-IMM node in
the bof>vc-stack-node command
- configure the TiMOS image location
The CPM-IMM nodes undergo an arbitration process where the node
assigned the lower slot number gets chosen as the active CPM node.
The node chosen as the active CPM node loads the TiMOS image and
boots up as the active CPM-IMM node. The standby CPM also proceeds
with boot up. However, it does not have the VC configuration on first-time
boot and needs to wait for the active CPM to provide the VC configuration
through VC management messages.
Step 9. Identify the node that will take on the IMM role.
Step 10. Ensure there is console access to the IMM node to drive the boot process.

Table of Contents

Other manuals for Nokia 7210 SAS-M