CLI Usage
Edition: 01 3HE 16132 AAAB TQZZA 79
Parameters mac-filter-id — Specifies the MAC filter policy ID.
Values 1 to 65535
entry entry-id — Displays information on the specified filter entry ID for the specified filter
ID only.
Values 1 to 65535
interval seconds — Specifies the interval for each display in seconds.
Default 5 seconds
Values 3 to 60
repeat repeat — Specifies how many times the command is repeated.
Default 10
Values 1 to 999
absolute — Keyword to display the raw statistics, without processing. No calculations
are performed on the delta or rate statistics.
rate — Keyword to display the rate-per-second for each statistic instead of the delta.
Output The following output is an example of MAC filter statistics.
Sample Output
A:ALA-1>monitor>filter# mac 50 entry 10 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for Mac filter 50 entry 10
===============================================================================
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
------------------------------------------------------------------------------
At time t = 3 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------
At time t = 6 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------
At time t = 9 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
===============================================================================
A:ALA-1>monitor>filter# mac 50 entry 10 interval 3 repeat 3 rate
===============================================================================
Monitor statistics for Mac filter 50 entry 10
===============================================================================
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------