G-240W-G unit data sheet
40
7368 ISAM ONT G-240W-G Product Guide
3FE-47555-AAAA-TCZZA Issue: 01
4.2.7 TR-104 voice-related alarms
The G-240W-G ONT supports the following four TR-104 voice-related alarms on a
per FXS port basis.
These alarms all represent SIP registration failures with an alarm level of MAJOR.
• SIPREGDNS: domain name could not be resolved
• SIPREGAUTH: authentication failed
• SIPREGTO: re-transmissions timed out
• SIPREGERFRSP: error response from the registration server
4.2.8 TR-104 parameters for FX line testing
New attributes have been added to the TR-104 Voice Service object structure to
enable the ACS to perform line tests. The ONT supports the following electrical line
tests:
• hazardous potential
• foreign electrical motive force
• resistive faults
• receiver off-hook test
• ringers test
4.2.9 TR-111 support
The G-240W-G ONT supports TR-111, which extends the WAN Management
Protocol defined in TR-069 to enhance the ability to remotely manage LAN devices.
The device-gateway association enables an ACS to identify the associated gateway
through which a device is connected.
A connect request via the NAT gateway enables an ACS to initiate a TR-069 session
with a device that is operating behind a NAT gateway.
4.2.10 TR-181 parameter support
TR-181 parameter support has been introduced or enhanced for the parameter
categories and functions listed in Table 4.
For details about which parameters are supported, see your Nokia representative.
Release 05.08.01a | August 2018 | Edition 01