AvoidmountingtheBTSsuchthattheantennasareblockedbyotherstructuressuch
aswalls.Adirectlineofsighttotheareatobecoveredwillprovidethebest
performance.
•
Keepothermetallicmountingfeaturesasfarawayfromallantennasaspossible.
•
KeepcablesroutedandsecuredawayfromtheLTEandBluetoothantennas.
•
RemotelylocatingtheBluetoothantennaisnotallowed.
•
Sinceonlyremotelyconnectedantennasaresupported,externallightningsurge
protectionmustbeadded.Formoreinformationonremotelymountingantennas,see
sectionInstallingantennas.
Ifsideclearanceislessthanscrewdriverlength,thegroundingcableneedstobepre-
installed.TheminimumandrecommendedmaintenanceclearancesareshowninTable
2:FlexiZoneMicroBTS(FWHR)maintenanceclearances.
Table2
FlexiZoneMicroBTS(FWHR)maintenanceclearances
BTS side Minimum clearances Recommended clearances
Front 50mm(1.97in) 500mm(19.68in)
Rear
35mm(1.38in)
(1)
35mm(1.38in)
(1)
Top 100mm(3.94in) Heightoftheunit+10mm
(0.39in)
Bottom 100mm(3.94in) 300mm(11.81in)
Left
10mm(0.39in)
(2)
10mm(0.39in)
(2)
Right 10mm(0.39in)
10/110mm(0.39/4.33in)
(3)
(1)
Forwallandpoleinstallations.
(2)
Forhorizontalpoleinstallationstheclearancemustbeatleast20mm(0.78in).
(3)
Dependsonthescrewdriverlength.
InstallingFlexiZoneMicroBTS InstallingandCablingFlexiZoneMicroHighPower
2x20WBTS
10 DN09229011 Issue:02