Nokiaproductsrequirepowerinjectorsthatsupporta12.5KOhmdetectionresistorand
provideapoweroutputof60Wperportina4PPoEimplementation.
Nokiarecommendedmidspandevicesarelistedinthetable.
Table5
Nokiarecommendedmidspandevices
Manufacturer Model Number of ports
Micro-semi PD-9606G 6
Micro-semi PD-9612G 12
Micro-semi PD-9501GR 1
Phihong POE480U-4UP 4
Phihong POE480U-8UP 8
Formoreinformationandspecifications,checkthemanufacturers'websites.
5.4 Installation options
ThischapterdescribesFlexiZoneIndoorPicoBTSpossibleinstallationscenarios,which
arewall,poleandceilinginstallations.
w
NOTICE:FlexiZoneIndoorPicoBTSequipmentmustbeinstalledbytrainedand
qualifiedservicepersonnelinaccordancewithalllocalcodesandrequirements.
w
NOTICE:FlexiZoneIndoorPicoBTSequipmentisintendedforinstallationinrestricted
accesslocationorequivalent.
w
NOTICE:Theunitmaybecomehotandshouldbeinstalledawayfromanypotential
sourcesofmoisture(awayfromheatingorcoolingducts,doors/window).Ensuregood
airflowfortheunittoallowproperheatdissipation.
w
NOTICE:TheunitshouldbelocatedawayfromanyRFradiationsources,outofdirect
sunexposure,andawayfromapotentialsaltspray.
w
NOTICE:Avoidinstallingthedevicenearwindowstoavoidexternalinterference.
w
NOTICE:Wheninstallingthemountingbracketontoaverticalpoleorawallensurethe
arrowspointupwards.
Forwall,poleandceilinginstallationinstructionsrefertotheFlexiZoneIndoorPicoBTS
QuickStartGuide.
TheFZPicoIndoormodulecanbeinstalledinthreepossibleways.
Flexi Zone Indoor Pico wall installation
g
UsethemountingbrackettoinstalltheFlexiZoneIndoorPicoBTSontoawall.
Construction FlexiZoneIndoorPicoBTSProductDescription
14 DN09210454 Issue:01