DRAFT
NOT FOR PUBLIC RELEASE
5
www.norcold.com/cda N500/N510 ModelsRefrigerator Service Manual
N510 Models
Storage volume
N510 --------------------------------------------------------------------------------------------------------------------------------- 5.5 ft
3
.
Rough opening dimensions (H x W x D)
N510 --------------------------------------------------------------------------------------------------- 42
5
/8
in. x 23
11
/16
in. x 24 in.
Decorative panels dimensions
Thickness---------------------------------------------------------------------------------------------------------------------------
3
/16
in.
Door panel dimensions (H x W) --------------------------------------------------------------------------------31 in. x 21
5
/16
in.
Controls
Type------------------------------------------------------------------------------------ Electronic with built-in diagnostic function
ON/OFF/MODE/TEMP SET switches ------------------------------------------------------------------ Flush pushbutton style
Temperature settings --------------------------------------------------------------------------------------------- 1=cold, 5=coldest
Temperature sensor --------------------------------------------------------------------------Thermistor, fin-mounted on 5
th
fin
Off-level operating limits
Side-to-side ----------------------------------------------------------------------------------------------------- 3 degrees maximum
Front-to-back --------------------------------------------------------------------------------------------------- 6 degrees maximum
DC power
Controls operating voltage ---------------------------------------------------------------------------------------- 10.5 to 15.4 Vdc
Controls DC fuse (F2 in power board) ----------------------------------------------------------------------------- 3 A type 3AG
DC operation voltage (3-way models only)------------------------------------------------------------------- 12 Vdc to 15 Vdc
DC heater rating (3-way models only) ------------------------------------ 10.7 amps @12 Vdc (resistance is 1.3 ohms)
DC amp draws (at nominal 12 Vdc)
Automatic ignition----------------------------------------------------------------------------------------------------------------- 0.50 A
Gas valve --------------------------------------------------------------------------------------------------------------------------0.146 A
AC power
AC heater operating voltage requirements ---------------------------------------------------------------------- 108 to 132 Vac
Fuse ac heater circuit (F3 in power board)----------------------------------- 5 A,
1
/4
in. x 1
1
/4
in. AGC type fast acting
AC heater rating ---------------------------------------------------------------- 200 W @ 110 Vac (resistance of 61.3 ohms)
LP gas (propane)
Operating pressure---------------------------------------------------------------------------------------------- 10.5 to 11.5 in. w.c.
Heat input--------------------------------------------------------------------------------------------------- 1200 Btu/h @ 11 in. w.c.
Orifice ---------------------------------------------------------------------------------------------------------------------------------LP10
Gas ignition --------------------------------------------------------------------------------- Automatic with flame-sensing circuit
Electrode-to-burner air gap ---------------------------------------------------------------------------------------------------
3
/16
in.