16
www.norcold.com
Polar Series N10LX, NA10LX
FAULT CODES - N10LX, NA10LX MODELS
Fault Code Fault Code Meaning Action to
Take
The burner did not ignite or re-ignite. Refer to “Fault Code - “no”
“FL” with Audible Alarm” on
page 17.
AC voltage is not available to the refrigerator. Refer to “Fault Code - “no”
“AC” with Audible Alarm” on
page 19.
AC heater fault. Refer to “Fault Code - “AC”
“HE” with Audible Alarm” on
page 20.
AC heater relay stuck on. Refer to “Fault Code - “AC”
“rE” with Audible Alarm” on
page 21.
DC input voltage to the refrigerator is low. Cooling is to
continue.
Refer to “Fault Code - “Lo”
“dc”” on page 21’
DC input voltage to the refrigerator is too low. GAS MODE is
inhibited. The refrigerator is not cooling.
Refer to “Fault Code - “Lo”
“dc” with Audible Alarm” on
page 21.
DC input voltage to the refrigerator is too low. All MODES
are inhibited.
Refer to “Fault Code - “Lo”
“dC” with Audible Alarm” on
page 21.
DC input voltage to the refrigerator is too high. Refer to “Fault Code - “HI”
“dc” with Audible Alarm” on
page 21.
Communications between the controls have been lost. Refer to “Fault Code - “no”
“dt” with Audible Alarm” on
page 22.
This fault is within the refrigerator controls. Refer to “Fault Code - “Sr”
with Audible Alarm” on
page 23.
This fault is within the refrigerator controls. Refer to “Fault Code - “oP”
“LI” with Audible Alarm” on
page 23.
A flame is sensed at the burner when there should be none
present.
Refer to “Fault Code - “FL”
“- -” with Audible Alarm” on
page 23.
The thermistor has been sensed as inoperable, so the tem-
perature is being controlled via backup operating system.
Refer to “Fault Code -
Flashing Temperature Set-
ting” on page 24.
The refrigerator will not turn ON. Refer to “Blank Display” on
page 25.
CODE CODE
Alternately flashes “no” and “FL”
with an audible alarm.
CODE CODECODE CODE
Alternately flashes “no” and “AC”
with an audible alarm.
CODE CODE
Alternately flashes “AC” and “HE”
with an audible alarm.
CODE CODE
Alternately flashes “AC” and “rE”
with an audible alarm.
CODE CODE
Alternately flashes “Lo” and “dc”.
CODE CODE
Alternately flashes “Lo” and “dC”
with an audible alarm.
CODE CODE
Alternately flashes “HI” and “dc”
with an audible alarm.
set
CODE
Flashes “Sr” with an audible alarm.
CODE CODE
Alternately flashes “oP” and “LI”
with an audible alarm.
CODE CODE
Alternately flashes “no” and “dt”
with an audible alarm.
CODE CODE
Alternately flashes “Lo” and “dc”
with an audible alarm.
CODE CODE
Alternately flashes “FL” and “--”
with an audible alarm.
set
Temperature setting flashes on/off at one (1)
second intervals any time the user interface
(control) is “awake”.
Blank display.