SERVICE MANUAL
23
www.norcold.com
Fault Code - “Sr” with Audible Alarm
Possible Cause:
The Main Control Board Assembly
(Power Board) detected an internal
fault. This fault can be displayed in any
MODE.
NOR000706A
Does
problem
continue?
YES
Solved.
NO
Replace Main Control Board Assembly
(Power Board Assembly).
To reset fault, power
refrigerator OFF and
then back ON.
Are gas
valve wires
plugged in?
NO
YES
Correct.
set
CODE
Flashes “Sr” with
an audible alarm.
Fault Code - “FL” “- -” with Audible Alarm
Possible Cause:
On the main control board assembly
(power board), the limit circuit is open.
Fault Code - “oP” “LI” with Audible Alarm
A ame is sensed at the burner when
there should be none present.
Possible Cause:
The gas valve is “mechanically” stuck
open. Therefore, the Main Control Board
(Power Board) senses a ame is pres-
ent at the burner when there should be
none
Replace Gas Train Assembly
The gas valve is
“mechanically” stuck open.
NOR000709A
CODE CODE
Alternately flashes “FL” and “--”
with an audible alarm.
CODE CODE
Alternately flashes “oP” and “LI”
with an audible alarm.
NOR000804A
Replace the Main Control Board
Assembly (Power Board).
On the Main Control Board
Assembly (Power Board),
the limit circuit is open.
Troubleshooting - N10LX AND NA10LX Models, cont’d.

Table of Contents

Other manuals for Norcold Polar N10LX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Norcold Polar N10LX and is the answer not in the manual?

Norcold Polar N10LX Specifications

General IconGeneral
BrandNorcold
ModelPolar N10LX
CategoryRefrigerator
LanguageEnglish

Related product manuals