SERVICE MANUAL
17
www.norcold.com
TROUBLESHOOTING - N10LX, NA10LX MODELS
Possible Cause:
No fl ame is sensed present at the
burner when there should be one.
The burner did not ignite or re-ignite.
This fault can occur in AUTO MODE or
MANUAL GAS MODE
Fault Code - “no” “FL” with Audible Alarm
CODE CODE
Alternately flashes “no” and “FL”
with an audible alarm.
Before starting this procedure:
■ Make sure that the valve of the RV propane gas tanks) is open.
■ Make sure that the manual shut-off valve of the gas train as-
sembly is open.
■ Make sure that the propane gas pressure to the refrigerator is
10.5 inches W.C.
YES
Clean burner.
NO
Is burner clean?
YES
Correct gap.
NO
Is burner/
electrode gap
1/8”-3/16”?
YES
Correct. Replace spark / sense
ignitor wire if needed.
NO
Spark/sense
wire installed
correctly w/
continuity?
YES
Replace gas train assembly.
NO
Gas valve
solenoid coil
resistance
74-92 Ohms?
Continued on following page.