Page #19 background imageLoading...
Page #19 background image
SERVICE MANUAL
19
www.norcold.com
Possible Cause:
There is no AC power to the refrigerator.
Fault Code - “no” “AC” with Audible Alarm
Before starting this procedure:
Make sure that no other problems exist with the vehicle’s AC
power supply.
Make sure no other appliances or lighting circuits are connected
to the refrigerator AC circuit.
Make sure that no extension cords are being used to supply AC
power to the refrigerator.
CODE CODECODE CODE
Alternately flashes “no” and “AC”
with an audible alarm.
NOR000714A
F2 fuse okay?
1. Check AC power input from RV to unit.
2. Check for faulty AC power cord.
NO
NO
YES
Check condition of F2 fuse
on main control board
(power board).
Replace fuse. Use a 5 amp,
1
/
4
" x 1
1
/4"
AGC type fuse.
108 to 132
VAC?
YES
Check that fuse holder clips
are making full contact with
fuse.
Adjust clips to ensure fuse contacts are
firm in clips and making full contact.
YES
Clips okay?
NO
Replace main control board assembly
(power board assembly).
Measure voltage at AC power
cord connection of the
main control board (power
board).
Troubleshooting - N10LX AND NA10LX Models, cont’d.

Table of Contents

Other manuals for Norcold Polar N10LX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Norcold Polar N10LX and is the answer not in the manual?

Norcold Polar N10LX Specifications

General IconGeneral
BrandNorcold
ModelPolar N10LX
CategoryRefrigerator
LanguageEnglish

Related product manuals