EasyManuals Logo

Norcold Polar N10LX Service Manual

Norcold Polar N10LX
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
20
www.norcold.com
Polar Series N10LX, NA10LX
Fault Code - “AC” “HE” with Audible Alarm
Before starting this procedure:
Make sure that the AC voltage to the refrigerator is 108-132
VAC.
Make sure no other appliance or lighting circuit is connected to
the refrigerator AC circuit.
CODE CODE
Alternately flashes “AC” and “HE”
with an audible alarm.
The AC is off when it should be on. AC
heater “lockout”. Turn the refrigerator
OFF and then back ON to reset.
Possible Cause:
AC heater fault.
The AC heater is not plugged in.
The AC heater failed open.
Heater
connections
okay?
NO
YES
Check AC heater resistance.
See figure, below.
NO
Replace AC heater.
YES
Replace main control board assembly
(power board assembly).
Check AC heater wires
for loose or damaged
connections
Resistance
38-50 Ohms?
Repair or replace connectors. If
connectors cannot be repaired,
replace AC heater.
Does
problem
continue?
NO
Solved.
YES
Reset by turning refrigerator
off and then back on.
NOR000715A-1
Troubleshooting - N10LX AND NA10LX Models, cont’d.

Table of Contents

Other manuals for Norcold Polar N10LX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Norcold Polar N10LX and is the answer not in the manual?

Norcold Polar N10LX Specifications

General IconGeneral
BrandNorcold
ModelPolar N10LX
CategoryRefrigerator
LanguageEnglish

Related product manuals