5. Carefully lift steam cylinder away from the cylinder receptacle, then
remove it to the front.
CAUTION!
Put steam cylinder down carefully to avoid damage to the lower con-
nection piece!
6. Carefully pull the drain screen out of the drain outlet of the steam cylinder.
Note: this step must only be carried out if the drain screen is clogged
(see chapter 8.2.2 “Unit faults”) and the steam cylinder can still be used.