Nordmann ES4 - Removal and Installation of the Drain Valve

Nordmann ES4
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
7.3.4 Removal and installation of the drain valve
For removing the drain valve the steam cylinder must be removed rst (see
chapter 7.3.1).
1. Detach electric cables (polarity of the cables must not be observed).
2. Release hose clamp and remove the hose from the connector.
3. Loosen the two screws with Phillips screwdriver, then remove the drain
valve.
4. Disassemble the drain valve.
The assembly and the installation of the drain valve follows the reverse
sequence. Before assembling the valve, check all Orings and gaskets for
damage and replace if necessary.
4
22
3
1

Table of Contents