DeviceNet Specifications
10-8
Part 1105120-03
E 2015 Nordson Corporation
Instance 100 – Input Assembly 1 (Common)
Byte
Index
Description
DeviceNet
Data Type
Class
ID
Instance
ID
Attribute
ID
0 Exception Status:
Defined in SDevice Supervisor Object
USINT 0x30 1 12
1 System Ready:
0 – Not Ready; 1 – Ready
USINT 0x64 0 100
2 – 3 Units Present Bitmap:
Bit 0 – Master
Bit 1 – Slave 1
Bit 15 – Slave 15
0 – Not present; 1 – Present
UINT 0x64 0 102
4 – 5 Fault Bitmap:
Bit 0 – Master;
Bit 1 – Slave 1
Bit 15 – Slave 15
0 – OK; 1 – Fault
UINT 0x64 0 101
6 – 7 Lamp Number
0: Master
115: Slaves
UINT N/A N/A N/A
8 Lamp State:
1 – Off
2 – Filament On Time Delay
3 – Standby
4 – Lamp Start
5 – Lamp On
6 – Fault
7 – Reset
8 – Cool Off
9 – Lamp Cool
10 – Test
11 – Start Power Delay
USINT 0x64 varies 103
9 Lamp Power Level:
0 100%
USINT 0x64 varies 106
10 – 13 Lamp Fault:
32bits Defined in SDevice Supervisor
Object
UDINT 0x64 varies 104