DeviceNet Specifications
10-9
Part 1105120-03
E 2015 Nordson Corporation
Instance 101 – Input Assembly 2 (Master/Slave 12)
Byte
Index
Description
DeviceNet
Data Type
Class
ID
Instance
ID
Attribute
ID
0 Exception Status
Defined in SDevice Supervisor Object
USINT 0x30 1 12
1 Status Bitmap
See Below
USINT 0x64 0 100, 101,
102
2 Master Lamp State
1 – Off
2 – Filament On Time Delay
3 – Standby
4 – Lamp Start
5 – Lamp On
6 – Fault
7 – Reset
8 – Cool Off
9 – Lamp Cool
10 – Test
11 – Start Power Delay
USINT 0x64 0 101
3 Master Lamp Power Level:
0 100%
USINT 0x64 0 102
4 Slave 1 Lamp State:
1 – Off
2 – Filament On Time Delay
3 – Standby
4 – Lamp Start
5 – Lamp On
6 – Fault
7 – Reset
8 – Cool Off
9 – Lamp Cool
10 – Test
11 – Start Power Delay
USINT 0x64 1 103
5 Slave 1 Lamp Power Level:
0 100%
USINT 0x64 1 104
6 Slave 2 Lamp State:
1 – Off
2 – Filament On Time Delay
3 – Standby
4 – Lamp Start
5 – Lamp On
6 – Fault
7 – Reset
8 – Cool Off
9 – Lamp Cool
10 – Test
11 – Start Power Delay
USINT 0x64 2 103
7 Slave 2 Lamp Power Level:
0 100%
USINT 0x64 2 104