Calculating Melter Power Requirements
A-2
Part 1032059B
E 2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
To evaluate the hose/gun power requirements
1. Identify all hose/gun pairs based on the hose/gun receptacle to which
they are connected.
2. Examine the identification tag or plate on each hose and gun and record
the wattage of each in Column A of Table A-1. Enter a zero for any hose
or gun that is not installed.
3. Add the wattages of each hose/gun pair and place the sum in Column B
of Table A-1.
4. Add the wattages of hose/gun pairs 1 and 2 and place the sum in
Column C of Table A-1.
5. Compare each of the wattages tabulated in Columns A, B, and C of
Table A-1 with the associated maximum allowable wattages in Table A-2
for 240 VAC melters or Table A-3 for 120 VAC melters.
6. Do one of the following:
S If each of the wattages calculated in step 5 do not exceed the
associated maximum allowable wattages listed in Tables A-2 and
A-3, then the power required by the hoses and guns is within
acceptable limits.
S If any of the wattages calculated in step 5 does exceed an
associated maximum allowable wattage listed in Tables A-2 and A-3,
then the configuration or position of the hose/gun pairs must be
rearranged, shorter hoses must be used, or lower power guns must
be used in order to reduce the power requirement.

Table of Contents

Other manuals for Nordson DuraBlue D4L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson DuraBlue D4L and is the answer not in the manual?

Nordson DuraBlue D4L Specifications

General IconGeneral
BrandNordson
ModelDuraBlue D4L
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals