Operation
4-13
Part 1032059B
E 2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
To view the temperature of a heated component
when an F2 or F3 fault exists, simultaneously
press and hold both of the right-display scroll
keys.
You can temporarily dismiss an F1 fault (RTD)
and return to the automatic scan mode by
pressing the Clear/Reset key. The heaters will,
however, remain off. If the fault condition still
exists two minutes after pressing the clear/reset
key, the fault LED will turn back on.
When an F1 fault code appears, you
can determine whether the fault was caused
by an open or a shorted RTD by
simultaneously pressing both of the right-display
scroll keys. If the right display indicates OP,
the RTD is open, if it indicates SH, the RTD
has shorted.
If, for any reason, a component reaches
235 _C (458 _F), an immediate F3 fault will occur
(no two-minute monitoring period).
If F4 appears in the right display when you press
the clock key, the internal clock function has
failed.

Table of Contents

Other manuals for Nordson DuraBlue D4L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson DuraBlue D4L and is the answer not in the manual?

Nordson DuraBlue D4L Specifications

General IconGeneral
BrandNordson
ModelDuraBlue D4L
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals