Operating Parameters
B-8
Part 1073401_07
E 2021 Nordson Corporation
Temperature Control
20 Temperature Units
Description:
Sets the units for temperature display.
Value:
C (degrees Celsius) or F (degrees Fahrenheit)
Resolution:
1 degree
Default Value:
C
Format:
—
Use:
—
21
Over Temperature Delta
Description:
The number of degrees that the temperature of any component can
increase over its assigned setpoint temperature before an over
temperature fault (F3) will occur.
Value:
5 _C (10 _F) to 60 _C (110 _F)
Resolution:
1_C
1_F
Default Value:
15 _C (25 _F)
Format:
—
Use:
—
22
Under Temperature Delta
Description:
The number of degrees that the temperature of any component can
decrease from its setpoint temperature before an under temperature fault
(F2) occurs.
Value:
5 _C (10 _F) to 60 _C (110 _F)
Resolution:
1_C
1_F
Default Value:
25 _C (50 _F)
Format:
—
Use:
—