Adjusting Component Temperatures
You can adjust the setpoint temperature of heated components using the
following methods:
S Global—The tank and all hoses and applicators are set to the same
setpoint temperature.
S Global‐by‐component group—All of the hoses or all of the
applicators are set to the same setpoint temperature.
S Individual Component—The setpoint temperature of the tank
and each hose and applicator is adjusted independently.
Before adjusting setpoint temperatures, confirm that each hose/applicator
pair is connected to the correct hose/applicator receptacle. For example,
hose/applicator pair 1 should be connected to the receptacle 1. Refer to
More About Heated Components earlier in this section for information about
hose/applicator positions.
To adjust setpoint temperatures using the global method
1. Press and hold the Tank key for three seconds.
The left display flashes 1.
2. Scroll the left display to 0 (flashing).
The right display indicates all dashes (‐‐‐‐) and the LEDs on all of
the component keys turn green.
3. Press a right‐display scroll key.
The right display flashes.
4. Use the right‐display scroll keys to enter the setpoint temperature
recommended by the manufacturer of the hot melt. Refer to the technical
data sheet provided by the manufacturer of the hot melt to determine the
optimal setpoint temperature.
NOTE: If the right‐display scroll keys have no affect on the right display,
the melter is password protected. You must enter a valid password
before you can change setpoint temperatures. Refer Enter the Melter
Password, later in this section.
5. Press the Tank key.
All components begin to heat or cool to the new global
setpoint temperature. When all of the components reach their
setpoint temperature, the ready LED turns on (green).

Table of Contents

Other manuals for Nordson DuraBlue D4L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson DuraBlue D4L and is the answer not in the manual?

Nordson DuraBlue D4L Specifications

General IconGeneral
BrandNordson
ModelDuraBlue D4L
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals