Operation
4-17
Part 1073401_07
E 2021 Nordson Corporation
Fault Log Examples
Example 1:
An unused log entry.
Example 2:
If the LED on the tank key were on, this log entry
would indicate that the tank is under temperature. If the LED on the hose key
were on, this log entry would indicate that hose 1 is under temperature.
To view the number of heater hours
that have elapsed since a log entry
was created, simultaneously press both
of the right‐display scroll keys. The
hours are indicated in the right display.
The melter will return to the automatic
scan mode if the fault log is left open for
a period of two minutes without any key
being pressed.
When an F1 fault is the result of a
hose/applicator pair being
disconnected from the melter, two fault
log entries are created. The first entry
is for the applicator and the second
entry is for the hose.