Installation
3-21
Part 1073401_07
E 2021 Nordson Corporation
Table 3-7 Change History Log
First Digit
Second
Digit
Third and Fourth Digits
P
(Parameter)
-
Indicates the number of the parameter that was changed
S (Setpoint)
Are used in conjunction with the LEDs on the component keys to indicate the location
and method of a setpoint temperature change.
When this LED is
on..
And the Fourth
Digit Indicates..
The change was
to..
And the Method
of Change was..
Tank Key 1 The tank Individual
Hose Key 1– 6 A single hose Individual
Applicator Key 1– 6 A single applicator Individual
All Keys 0 All components Global
Hose Key 0 All hoses
Global‐by‐
component
Applicator Key 0 All applicators
Global‐by‐
component
Change History Log Examples
Example 1:
Parameter 4 (ready delay) was changed.
Example 2:
If the LED on the applicator key is on, then this display would
indicate that the global‐by‐component method was used to change the
temperature of the applicators.
Unused log entries in the change history log are
indicated by “P-_” in the right display.
To view how many heater hours have elapsed
since a specific change (displayed) was made,
simultaneously press both of the right-display
scroll keys.