Operation
4-22
Part 1603227-12
E 2016 Nordson Corporation
Opening the Function Menu and Making Settings (contd)
Function 01, Value 00 Function 01, Value 01
Figure 4-22 Displaying and Changing Configuration Functions
Table 4-1 Function Settings
Function
Number
Function
Name
Function
Values
Default
Value
F00 Gun Type 00=Encore 00
F01 Fluidizing 00=Hopper, 01=Box, 02= Disable 00
F02 Display Units 00=SCFM, 01=M
3
/HR 00
F03 Electrostatic Control 00=Custom, 01=Classic (STD, AFC) 00
F04 Powder Flow Control 00=Smart, 01=Classic 00
F05 Keypad Lockout 00=Unlocked, 01=Locked 00
F06 Vibratory Box Delay Off on, 00−90 seconds (on=continuous operation) 30 sec
F07 Maintenance Timer 00=Disable, 00−999 hours 00
F08 Settings Trigger
Function
00=Increase/Decrease Preset or Flow,
01=Disable, 02=Flow only, 03=Preset only,
04=Purge, 05=Trigger
00
F09 Help Codes 00=Enable, 01=Disable 00
F10 Zero Reset (Flow) 00=Normal, 01=Reset (See Note below) 00
F11 Gun Display Errors 00=Flashing, 01=Disable 00
F12 A Lower Limit 00=10 A, 01=5A, 02=1 A 00
F13 A Upper Limit 00=50 A, 01=100 A 00
F14 Total Hours View Only −
F15 Save/Restore/Reset 00=System Save, 01=System Restore,
02=Factory Reset
00
F16 Gun Display Brightness 00=Low, 01=Medium, 02=Maximum 01
F17 Number of Presets 01−20 presets 20
NOTE: Refer to Section 4, Troubleshooting for the Zero Reset procedure.