Data Configuration Procedure
This example sets the process value data to display:
1. Press the Select key to enter configuration mode. Press the Select key
to scroll through the configuration menu items.
2. On DATA press the Enter key.
3. Use the Up and Down Arrow keys to scroll through the data items.
4. Press the Enter key to select a data item. Yes appears if the item was
selected for display previously, No if it was not.
5. Use the Up or Down Arrow keys to toggle between Yes to display or No
to not display.
6. Press the Enter key to select Yes or No. SAVE appears, then
disappears and the data item name appears.
7. Use the Up or Down Arrow keys to scroll through the rest of the DATA
menu items.
8. Press the Select key to exit the DATA menu.
Configuration - PRx Module Data
Make the following required and optional settings to configure the Remote
Display to display PRx module data. See Figure 6 for the menu map.
Menu Function and Default
MODE Mode to enter: DISP (Display mode) or CONF (Configuration mode). Pressing the Select
key while in Display mode automatically sets the mode to CONF. Select DISP to return to
display mode from configuration mode. On power up the factory default is DISP.
INTR Display Interval (1-60 seconds): Time to display each process data value. If more than
one process data is selected, each data value is display for this time, in sequence.
Default is 5 seconds.
COMM Set communications protocol: CAN1, CAN2, 485 (RS485). Set to 485 for PRx modules.
The factory default is RS485.
DATA Process data to display: BASE (base pressure), TEMP (fluid temperature), RPM (belt
speed). The factory default is BASE only. If more than one is chosen for display, then
each is displayed in sequence.
NOTE: To configure the process data, refer to the Data Configuration procedure above.
UNIT Display units: ENGL (English) or METR (Metric). The factory default is English.
ADDR 1-4. The factory default is 2. The PRx module is always set to 1.