iTRAX Remote Display
6
Part 1076079A
E 2007 Nordson Corporation
Configuration
The Remote Display configuration procedure changes depending on the
devices it is used with: iTRAX Spray Monitors or an iTRAX PRx module.
When the Remote Display is powered up it goes through a self test and
then loads the configured settings. If no settings have been made then it
loads the defaults.
The Remote Display has two modes, Display mode and Configuration
mode. In Display mode the Process Data display shows the configured
process data, and the Units display shows the relevant engineering units for
the process data. In Configuration mode the Process Display shows CONF
and the Units Display is used to make the configuration settings. On power
up the Remote Display defaults to Display mode.
Entering Configuration Mode
Press the Select key to enter Configuration mode from Display mode.
CONF is displayed on the Process Display; the version number is displayed
on the Units Display.
Configuration Menu Navigation and Settings
Use these procedures to navigate through the configuration menus and
configure the Remote Display.
S Press the Select key to move from one configuration menu to the next,
as shown in Figures 5 6.
S Press Enter to open a menu. Use the Up and Down keys to scroll
through the menu items.
S Press Enter to select a menu item and save it to memory.
S Press Select to return to the configuration menu.
Returning to Display Mode
To return to Display mode for normal operation:
1. Press the Select key until MODE is displayed.
2. Press the Enter key, then press the Up or Down Arrow keys to scroll to
DISP.
3. Press the Enter key to enter Display mode. The Process Value display
will display four dashes, then start displaying process values, starting
with the first configured gun channel.