iTRAX Remote Display
2
Part 1076079A
E 2007 Nordson Corporation
Operator Interface
Process Data Display: Displays process data.
Nordson Key: Toggles the scrolling of process data and gun channels on
and off. Press once to lock, again to unlock.
Units Display: In Display mode, displays the Engineering Units for the
currently displayed process data. In Configuration mode, displays
configuration menus and settings.
Gun LEDs: Light to indicate the spray monitor (gun) for which process data
is being displayed.
Select Key: Press to enter Configuration mode and to scroll through the
configuration menus.
Arrow Keys: Press to scroll through the selections available in each menu.
Enter Key: Press to accept a selection and to store a selected value in
memory.
Process
Data
Select
Up
(Increase)
Down
(Decrease)
Enter
Units Display
Gun 1
LED
Gun 2
LED
Gun 3
LED
Gun 4
LED
Nordson
Key
(Scroll
Lock/
Unlock)
Figure 1 Remote Display Operator Interface
Specifications
Dimensions: 5.5 L x 2.875 W x 3.937 H (not including mounting bracket)
Power: 24 Vdc
Communications: Proprietary 500K baud CAN protocol (Spray Monitors)
or 9600 baud RS485 MODBUS RTU (Pressure Controller)