Troubleshooting
6-34
Part 1024496_06
2014 Nordson Corporation
Continued from previous page....
+
+
Are the tank and the manifold
TRIACs functioning properly?
Refer to DP.4.
+
Is the resistance correct for the
tank and the manifold heaters?
Refer to DP.5.
Does replacing the malfunctioning
tank or manifold RTD solve the
problem?
P/N 1028320.
Refer to DP.2.
Stop.
Replace the main board.
P4/P7 P/N 1028322.
P/10 P/N 1028323
Replace the manifold heater,
tank, or the power harness.
Manifold heater P/N 1017723.
Tank P/N 1018379.
Power harness P/N 1024529.
Contact Nordson for technical
assistance.
Starting conditions:
Fault LED is illuminated >
F2 fault exists >
Tank key LED is illuminated >
Hot melt has not been added
T.2.3

Table of Contents