Technical Data
8-2
Part 1024496_06
2014 Nordson Corporation
Electrical Specifications
Item Data Note
Hose/gun heating capacity 2, 4, or 6 hose/gun pairs
A
Control temperature range 40 to 230 C (100 to 450 F)
Control temperature accuracy 1 C
B
International Protection (IP) rating IP54
Input voltage tolerance +10%, -15%
NOTE A: Dependent on melter configuration and addition of optional hose/gun modules
B: Flow set-point at RTD
Pump Specifications
Item Data
Air pressure while running 70 to 689 kPa (10 to 100 psi)
Minimum air pressure 0.7 bar (10 psi)
Viscosity range 800 to 10,000 cps
Maximum hydraulic pressure
15:1 pump: 10.3 MPa (1500 psi)
6:1 pump: 4.14 MPa (600 psi)
Air consumption at 415 kPa (60 psi) and maximum pump
speed
46 l/min. (1.6 scfm)
Displacement 7.20 ml/stroke ( 0.44 in
3
/stroke)
Maximum speed 90 strokes/min.
Melter Power Requirements
Melter
Number of
Hose/Guns
1‐Phase Power
Draw (Amps)
3‐Phase Power (Amps)
Without Neutral With Neutral
P4
2 17 15 9
4 26 23 17
P7
2 18 16 10
4 27 24 17
P10
2 18 16 10
4 27 24 17
6 35 31 18