Operating Parameters
B-11
Part 1024496_06
2014 Nordson Corporation
34 – 39
Optional Inputs 5, 6, 7, 8, 9, and 10
Description:
Control options that determine the function of the six optional inputs
provided when the optional I/O expansion card is installed on the CPU
board.
Value:
0 – Input Disabled
1 – Standby On/Off
2 – Heaters On/Off
3 – Pump Enable/Disable
4 – Hose/Gun 1 Enable/Disable
5 – Hose/Gun 2 Enable/Disable
6 – Hose/Gun 3 Enable/Disable
7 – Hose/Gun 4 Enable/Disable
8 – Hose/Gun 5 Enable/Disable
9 – Hose/Gun 6 Enable/Disable
11 – Motor 2 Enable/Disable (DuraBlue adhesive melters only)
Resolution:
1
Default Value:
0 (disabled)
Format:
Use:
Multiple inputs can be set to the same input value. After one or more
inputs that have the same input value are energized, the input
functionality will not be considered inactive (off) until all of the inputs
with the same input value are de-energized (Multiple inputs set to the
same input value are logical ORed.).